SEUIR Repository

Automated ventilation system for maintaining indoor co2 concentration to reduce allergic and respiratory diseases: for rural area in Batticaloa, Sri Lanka

Show simple item record

dc.contributor.author Pirapuraj, P.
dc.contributor.author Minnoli, N. V.
dc.contributor.author Saranraj, M.
dc.date.accessioned 2021-11-01T06:52:00Z
dc.date.available 2021-11-01T06:52:00Z
dc.date.issued 2021-08-29
dc.identifier.citation Asian Conference on Innovation in Technology (ASIANCON);2021; p.1-8. en_US
dc.identifier.issn 9781728184029
dc.identifier.uri https://doi.org/10.1109/ASIANCON51346.2021.9544870
dc.identifier.uri http://ir.lib.seu.ac.lk/handle/123456789/5825
dc.description.abstract Ventilation is essential to expel indoor generated pollutants from indoor air or weaken their focus to satisfactory levels. CO2 and bio-effluents are natural products of human metabolism, but consuming high CO2 levels can result in unhealthy symptoms such as sore throat, irritated nose/sinus, combined mucous membrane, tight chest, etc., wheezing. The modern air conditioner is designed to exhaust polluted indoor air. Ventilation is not an issue for those who rich enough. But indoor polluted air is a big problem for the middle-class and poor. As part of this study, the homes of 20 middle-class families (Families with at least one Pulmonary patient were chosen) with different numbers of occupants were inspected among 50 selected families. As part of the inspection, the concentration of CO2 in the families' bedrooms was ceaselessly measured over an average of 3 days. An average CO2 concentration was recorded at night in bedrooms of all families, 03 bedrooms had below 1000 ppm, and 17 bedrooms had above 2000 ppm, and in 03 bedrooms had above 4000 ppm. The CO2 concentration was recorded in the identical bedrooms after deploying the developed Automated Ventilation System. Our system and architecture have 100% of efficiency in maintaining the bedroom CO2 concentration below 1000 ppm. en_US
dc.language.iso en_US en_US
dc.publisher IEEE en_US
dc.subject Ventilation en_US
dc.subject Polluted indoor air en_US
dc.subject Co2 en_US
dc.subject Bioeffluents en_US
dc.subject Wheezing en_US
dc.subject Pulmonary patient en_US
dc.subject Co2 Sensor en_US
dc.title Automated ventilation system for maintaining indoor co2 concentration to reduce allergic and respiratory diseases: for rural area in Batticaloa, Sri Lanka en_US
dc.type Article en_US


Files in this item

This item appears in the following Collection(s)

  • Research Articles [915]
    THESE ARE RESEARCH ARTICLES OF ACADEMIC STAFF, PUBLISHED IN JOURNALS AND PROCEEDINGS ELSWHERE