SEUIR Repository

Comparing the effect of delayed serum separation on Creatinine measurement by Jaffe and Sarcosine oxidase enzymatic methods with different time and temperature

Show simple item record

dc.contributor.author Shamil Mafras, Fathima Siromiya
dc.date.accessioned 2023-01-05T05:12:37Z
dc.date.available 2023-01-05T05:12:37Z
dc.date.issued 2021-12-30
dc.identifier.citation Sri Lankan Journal of Technology (SLJoT), 2(2); pp.1-5. en_US
dc.identifier.issn 2773-6970
dc.identifier.uri http://ir.lib.seu.ac.lk/handle/123456789/6398
dc.description.abstract —Creatinine is a nitrogenous organic waste product and increased in serum under abnormal renal function. Commonly used methods for creatinine measurement are Jaffe and Sarcosine Oxidase enzymatic methods. Delays in serum separation may cause changes in serum creatinine level. This could lead to misclassification of the stages of Chronic Kidney Disease. The study was carried out in normal pooled serum to find the changes in the serum creatinine levels of normal individuals, if the blood is stored for different periods and the serum separation is delayed. Ten milliliters (10 mL) of blood from 3 healthy individuals were pooled, equally divided and were stored. Creatinine concentrations in the serum immediately separated from the blood samples which were stored for 2 and 6 hours & 1, 2 & 3 days, at room temperature (≈ 27 − 29◦C) & in a refrigerator were measured. The results indicated that the Sarcosine Oxidase enzymatic method gives more accurate values of serum creatinine level than the Jaffe method. Samples can be stored at room temperature for 6 h without significant change in creatinine concentration (p<0.5) and refrigerator is the best method for delayed serum separation (p<0.5). en_US
dc.language.iso en_US en_US
dc.publisher Faculty of Technology, South Eastern University of Sri Lanka en_US
dc.subject Creatinine en_US
dc.subject Jaffe method en_US
dc.subject Sarcosine Oxidase en_US
dc.subject Enzymatic assay en_US
dc.subject Chronic Kidney Disease en_US
dc.title Comparing the effect of delayed serum separation on Creatinine measurement by Jaffe and Sarcosine oxidase enzymatic methods with different time and temperature en_US
dc.type Article en_US