Please use this identifier to cite or link to this item: http://ir.lib.seu.ac.lk/handle/123456789/6178
Title: Model base optimized solution to eliminate “No water” complain at the water supply distribution network of Ampara water supply scheme
Authors: Jaawahir, I. L. M.
Faaique, M. M. M. A.
Suja, A. C. A.
Keywords: Drinking Water Supply
Dynamic Hydraulic Model
Pipelines
Storage Tank
Issue Date: 25-May-2022
Publisher: South Eastern University of Sri Lanka, Oluvil, Sri Lanka.
Citation: Book of Abstracts - Proceedings of the 10th International Symposium 2022 on "Multidisciplinary Research for Encountering Contemporary Challenges”. 25th May 2022. South Eastern University of Sri Lanka, Oluvil, Sri Lanka. pp. 49.
Abstract: The pipe-borne drinking water supply systems have been in operation since the colonial period in Sri Lanka. After the Independence, and with the involvement of the Galoya Development Board, the water supply system was developed covering the township of Ampara district also, and it was later taken over by National Water Supply & Drainage Board. The distribution system was extended from time to time in surrounding areas in an ad-hoc manner. There was no proper hydraulic model available to identify the sizes of pipes and capacity of storage required to satisfy the demand without any “no water” complaint. Hence, this research was undertaken to identify whether the existing system is adequate to supply water to satisfy the required demand in the Ampara region. Furthermore, this study also covered the capacity of storage tanks and sizes of pipelines required to satisfy the demand after ten years and twenty years of period. In this research, Existing pipe networks of the Ampara region were drawn in Arc-GIS and WaterGem model was developed to identify the pipe sizes and storage capacity of tanks. The results show that, since the existing elevated storage tanks are not enough for direct supply throughout the day, the network bypassed the pumping pipeline. Moreover, storage tanks were used as balancing tanks while introducing necessary controls. Furthermore, to maintain limited residual pressure and required flow in the system, a variable frequency drive pumping system is introduced at the pumping station and inconsistency in the network model has been improved while introducing necessary changes for physical components. The proposed physical changes are documented for construction relevant to this field in the future.
URI: http://ir.lib.seu.ac.lk/handle/123456789/6178
ISBN: 978-624-5736-37-9
Appears in Collections:10th International Symposium - 2022

Files in This Item:
File Description SizeFormat 
IntSym2022BookofAbstracts-49.pdf495.12 kBAdobe PDFThumbnail
View/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.