Please use this identifier to cite or link to this item: http://ir.lib.seu.ac.lk/handle/123456789/7093
Title: Effect of brewing time and temperature on microbial load in Ceylon black tea
Authors: Amarasena, N. D. U. D.
Hettiarachchi, H. A. P. W.
Guruge, K. P. G. K. T.
Maduwanthi, S. D. T.
Keywords: Brewing temperature
Brewing time
Total plate count
Yeast and Mould Count
Issue Date: 6-Mar-2024
Publisher: Department of Biosystems Technology South Eastern University of Sri Lanka Sri Lanka
Citation: Book of Abstracts, 1st Undergraduate Research Colloquium Department of Bio systems Technology, South Eastern University of Sri Lanka, pp. 50.
Abstract: Tea is one of the most popular beverages consumed worldwide. However, during the production process, made tea can get contaminated with microorganisms. This study was conducted to measure the microbial contamination in made tea samples and the respective tea brew samples brewed using a set of selected time temperature combinations. Contaminated black tea samples were used for the analysis. Samples were analyzed for its microbial load before brewing and after brewing at 700C, 850C,1000C for 3,5,6 minutes. The Total Plate Count (TPC), Yeast and Mould Count and Total Coliform Count was done following (ISO 4833 -1:2013), (ISO 21527- 2:2008) and (ISO 4831:2006) methods. The study found that the TPC, Yeast and Mould Count and Total coliform counts were 7.9×105 ± 1.2×105 CFU g1 , 5.1×103 ± 1.5×103 CFU g-1 , and >1100 MPN-g in contaminated made tea samples before brewing. All brewing conditions reduced TPC in tea by more than 99.8%, with the exception of 3 minutes at 70°C, where a reduction of 97.1 % was recorded. Similar behavior was observed in Yeast and Mould count as more than 98.0% reduction was occurred by all brewing conditions. The reduction of microbial load by brewing was significant at 95% confidence level (P<0.05). Total Coliform was reduced to <0.3 MPN-g in all brewed samples regardless of the time and temperature. Furthermore, there was no considerable difference in reduction of microbial load between times of brewing or temperatures. The study reveals that microbial load in made tea is reduced to a considerable level in brewing.
URI: http://ir.lib.seu.ac.lk/handle/123456789/7093
ISBN: 978-955-627-023-5
Appears in Collections:Undergraduate colloquium - 2024

Files in This Item:
File Description SizeFormat 
(Colloquium ) Book of Abstract - Undergraduate research conference final e-version - 50.pdf267.44 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.